ORDER NO. MD0303079S0

A6

CD Stereo System

Subject: Information on Cold Start Setting

Please file and use this supplement manual together with the service manual for
Model No.SA-PM17P/PC-S, Order No.MD0205107C1,
Model No.SA-PM17E/EB/EG-S, Order No.MD0205132C2,
Model No.SA-PM17GD/GN-S, OrderNo.MD0207185C3.

© 2003 Matsushita Electronics (S) Pte. Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law.

1 Cold Start Setting

1.1 Doctor Mode Setup

  1. Set to ‘TAPE’ mode.

  2. To enter Doctor mode, input 4 then 7 from the remote control while pressing STOP key of the main set.

  3. The CLEAR key on the remote controller shall end the test and exit Doctor Mode.

  4. When plug out from Doctor mode, it will reset start when plug in back.

1.2 Cold Start Setting

  1. Doctor mode ON.

  2. Remote control SLEEP key ON.

    • Data shall be set in order to make a cold start (backup data are initialized) when reset starts next time.
      To clarify that the code was accepted at this time, the pattern below is displayed in the LCD upper row for 2 seconds.

    Note : In the case that you unplug from AC outlet after this mode was set, then plug to AC again, a cold start shall begin.

M0303 L


TOP